MATERIAL SAFETY DATA SHEET
|
|
Rapid Blanket Restorer Corp.
P.O. Box 674
Chesterland, Ohio 44026-0674
Business Phone Number: 330-821-6326
Prepared: 12-10-92 Revised: 03-30-05
EMERGENCY: 800-424-9300 Chemtrec-24 Hour - Only for spills, leaks,fires,
exposure or
accidents involving chemicals.
|
|
I. PRODUCT IDENTIFICATION
|
|
Product Name: ENVIRO BLANKET RESTORER
|
General ID: Solvent Blend
DOT Hazard Classification: Combustible Liquid, PG III
DOT Shipping Name (49 CFR172.101-102): Combustible Liquid, n.o.s. (NMP)
DOT Description: Drums - Combustible liquid; UN/NA 1993 (bulk) |
|
II. Hazardous Components
|
|
Ingredient
|
CAS NUMBER
|
PEL(ppm)
|
TLV(ppm)
|
%
|
|
N-Methyl Pyrrolidone
|
872-50-4
|
100
|
100
|
98-99%
|
|
Hydroxypropyl Cellulose
|
9004-64-2
|
|
|
1-2%
|
|
III. Physical Data
|
|
Boiling Point (deg C):
|
203° C
|
| V.O.C.: |
8.47 lb./gal |
|
Specific Gravity
|
1.03 (Water=1)
|
| % Volatile by Weight: |
98.76 |
|
Vapor Pressure:
|
(mm Hg@20C) < 1 mbar
|
| Evaporation Rate: |
Slower than Butyl Acetate |
| pH: |
7.0-7.5 (100gm/liter of water) |
|
Solubility in Water:
|
Complete
|
| Odor: |
Amine-like |
|
Hazardous Polymerization:
|
Not expected to Occur
|
|
Materials to Avoid:
|
Strong Oxidizing or reducing agents
|
|
Hazardous Decomposition Products:
|
Carbon Monoxide and Nitrogen Oxide
fumes produced when heated to decomposition.
|
|
IV. Fire and Explosion Data
|
|
Flash Point (Closed Cup Test Method):
|
199° F (ASTM
D 93-73
|
|
Auto ignition Temperature:
|
518° F (DIN 51794)
|
|
Flammability Limits in Air (% by volume):
|
Lower 1.3, Upper 9.5%
|
|
Extinguishing Media:
|
Water Fog, Dry Chemical CO2, Foam
|
|
Special Firefighting Procedures:
|
Wear NIOSH-MSHA approved, self-contained breathing
apparatus and turn out gear.
|
|
Unusual Fire & Explosion Hazards:
|
Low, when exposed to heat or flames. Can react
with oxidizing materials
|
|
V. Reactivity Data
|
|
Stability:
|
Stable.
|
|
Conditions to Avoid:
|
Heat, flames, moisture-compound is hygroscopic.
|
|
Chemical Incompatibility:
|
Strong acids, oxidizing agents
|
|
Hazardous Decomposition or Byproducts:
|
Carbon Monoxide, Carbon Dioxide and Nitrogen
Oxide
|
|
Hazardous Polymerization:
|
Not expected to occur
|
|
Corrosive to Metal:
|
No
|
|
Oxidizer:
|
No
|
|
VI. Health Data
|
|
Acute Health Effects (Short Term):
|
Severe eye irritant. Temporary clouding. Moderate
skin irritant, not a sensitizer. Slight skin absorption hazard. Slight ingestion
hazard, gastrointestinal tract irritant.
|
|
Chronic Health Effects (Long Term):
|
Not carcinogenic in rats exposed to 0.4MG/L
of vapors for 2 years. Not Mutagenic in AMES Test. Not teratogenic
by dermal exposure at levels tolerated by mother in animal studies.
Prolonged skin contact causes redness, irritation, defatting
and contact dermatitis.
|
|
First Aid:
|
|
Eyes:
|
Flush with flowing water for at least 15 minutes.
Get medical attention.
|
|
Skin:
|
Wash affected areas thoroughly with water
while removing contaminated clothing. Get medical attention. Wash
clothes before reuse.
|
|
Inhalation:
|
Move to fresh air. Aid in breathing, if necessary
and get medical attention.
|
|
Ingestion:
|
Dilute with warm water. Do not induce vomiting.
Get immediate medical attention. NEVER GIVE FLUIDS OR INDUCE VOMITING
IF PERSON IS UNCONSCIOUS OR HAVING CONVULSIONS.
|
|
VII. Environmental Data
|
|
Toxicity Data:
|
Not established
|
|
Spill or Leaks:
|
Not a regulated product. Spills should be
contained absorbed and placed in suitable containers for disposal.
|
|
Waste Disposal:
|
Incinerate or bury as a solid after absorption
on cementation in licensed facility. Do not put in sewers or waterways.
Containers should be crushed to prevent reuse and disposed in
licensed facility.
|
|
SARA Act of 1986, Title III:
|
Section 311/312 Hazard Categories - Fire Hazard
Section 313 - No chemicals in this product exceed the de minimus
reporting level established by SARA Title III Section 313 and
40 CFR 372.
|
|
Toxic Substance Control Act (TSCA)-
|
All components listed on TSCA list.
|
|
Comprehensive Environmental Response, Compensation
and Liability Act (CERCLA):
|
No chemicals in this product are subject to
reporting requirements of CERCLA.
|
|
VIII. Other Special Protection and Precautions
|
|
Respiratory Protection:
|
Use approved organic vapor respirator if vapors/mists.
|
|
Ventilation:
|
Local exhaust to recommended P.E.L.
|
|
Clothing:
|
Gloves, coveralls, apron to minimize skin
contact
|
|
Eye Protection:
|
Goggles
|
|
HMIS Health:
|
2
|
|
Flammability:
|
1
|
|
Reactivity:
|
0
|